Tiếng Việt
  1. Home
  2. Doctors
  3. PET/CT Imaging at Vinmec Times City
PET/CT Imaging at Vinmec Times City - Hình 1
1 / 4

PET/CT Imaging at Vinmec Times City

Vinmec Times City currently operates the GE Discovery MI DR PET/CT system with a 128-slice CT from the United States, helping patients achieve early cancer detection and effective treatment through high-quality healthcare services and an experienced team of experts.

Languages: Vietnamese, English

Schedule at facilities
Bệnh viện Đa khoa Quốc tế Vinmec Times City

Times City T11, 458 Pho Minh Khai, Khu do thi Times City, Hai Ba Trung Ward, Hanoi, Hanoi

Mon - Fri: 08:00-12:00, 13:00-17:00

Sat: 08:00-12:00

About PET/CT Imaging at Vinmec Times City

In oncology, detecting disease at an early stage or accurately identifying metastatic sites is critical to patient survival. As the first private hospital in Vietnam to implement PET/CT technology, Vinmec Times City International Hospital has established itself as a leading reputable address, providing thousands of cancer patients with targeted diagnostic and therapeutic opportunities thanks to its state-of-the-art technology and JCI-accredited international-standard services.

What is PET/CT imaging?

PET/CT imaging combines two methods: PET (measuring cellular metabolism) and CT (localizing anatomical structures). This allows physicians at Vinmec to clearly visualize minute lesions and biochemical abnormalities in cells even before organ structures have changed. Traditional methods such as ultrasound, X-ray, or even standard CT/MRI may easily miss these findings.

The procedure involves injecting a radioactive tracer into the patient's body. The PET/CT scanner then records abnormal signals, enabling physicians to comprehensively evaluate both anatomical morphology and the biochemical activity of organs in a single session.

The Role of PET/CT in Oncologic Diagnosis and Treatment at Vinmec

In current clinical practice, over 90% of cases indicated for PET/CT imaging involve cancer or suspected cancer, aiming to differentiate between benign and malignant lesions, identify primary tumors, distant metastases, or paraneoplastic syndromes. Additionally, PET/CT is applied in the diagnosis of neurological, cardiovascular, and infectious diseases.

At Vinmec Times City, PET/CT imaging services are comprehensively integrated into multimodal therapy pathways, delivering superior outcomes:

  • Screening and Early Detection: Localizing malignant tumors at the initial stage when patients do not yet exhibit clinical symptoms.
  • Accurate Disease Staging: Precisely determining tumor size and whether cancer cells have spread to lymph nodes or metastasized to distant organs (bones, liver, brain, etc.). Accurate staging helps optimize treatment regimens and avoids unnecessary major surgery if distant metastasis has occurred.
  • Treatment Response Assessment: Helping physicians determine whether the tumor responds to chemotherapy or radiation therapy based on the reduction in radioactive glucose (FDG) uptake. If ineffective, the regimen is immediately adjusted to save "golden time" for the patient.
  • Early Detection of Recurrent Cancer: Accurately differentiating between old scar tissue following surgery/radiation therapy and insidiously recurring cancer cells.
  • Radiation Treatment Planning Simulation: Precisely determining the coordinates and volume of the target area containing active cancer cells, ensuring radiation beams hit the target, maximize tumor destruction, and protect surrounding healthy tissue.

large_20200602_091841_875852_chup_pet_ct_co_an_t_max_1800x1800_jpg_cfbb5f8024

Why Choose PET/CT Imaging at Vinmec Times City

World-Leading Advanced PET/CT System

  • Vinmec Times City is equipped with the GE Healthcare (USA) Discovery MI DR 128-slice PET/CT system. This is one of the most modern models with outstanding advantages:
  • Ultra-High Sensitivity and Resolution: Capable of detecting extremely small lesions measuring only a few millimeters.
  • Rapid Scan Time: Reduces scanning time by half compared to older models, enhancing patient comfort during the procedure.
  • Low-Dose Technology: Minimizes radiation exposure to the patient's body while ensuring absolutely sharp image quality.

Leading International and Domestic Expert Team

The entire process of scanning, reading results, and consultations at Vinmec Times City is performed by a team of physicians and nuclear medicine specialists with extensive experience, rigorously trained at major medical centers abroad (USA, France, South Korea, etc.).

Simultaneously, Vinmec applies the Multidisciplinary Tumor Board model—coordinating radiologists, nuclear medicine physicians, medical oncologists, surgeons, and radiation therapists—to provide accurate conclusions and optimal individualized treatment regimens.

VIP-Grade Service Space with Absolute Safety

  • JCI-Compliant Radiation Safety: The production, transport, and injection of FDG radioactive tracers are strictly controlled by automated systems within isolated areas, ensuring absolute radiation safety for patients according to US standards.
  • Comfortable Rest Experience: Customers are provided with private, quiet waiting rooms before and after medication administration. Standard lighting systems help promote relaxation and reduce anxiety.
  • Attentive 1:1 Care: Nursing staff accompany and support patients at every step of the process, from scheduling to completion of the scan.

International-Standard PET/CT Imaging Procedure at Vinmec Times City

To ensure a smooth procedure and the most accurate results, patients must cooperate in following this process:

  • Before the Scan Day (24–48 hours): Patients should follow a low-carb, low-sugar diet; avoid strenuous exercise or heavy physical activity. Keep the body well-warmed.
  • Fasting: Strictly fast for at least 4–6 hours before the scheduled scan time. Only pure water may be consumed (no milk, coffee, or soft drinks).
  • Blood Glucose Check: Upon arrival at the hospital, the patient's blood glucose level will be measured. The scan can only proceed if the blood glucose index reaches a safe level (< 11 mmol/L or < 200 mg/dL). Diabetic patients must inform their physician in advance to receive appropriate medication instructions.
  • Radioactive Tracer Injection: The patient receives a small dose of the radioactive drug 18F-FDG via intravenous injection.
  • Rest Period Waiting for Uptake (60 minutes): The patient rests completely in an isolated waiting room, maintaining a relaxed mental state, avoiding talking or using mobile phones to prevent the radioactive tracer from accumulating incorrectly in active muscle regions. Before entering the scanner, the patient must empty the urinary bladder.
  • Scanning Process: The time spent on the examination table lasts approximately 15–20 minutes. The patient must maintain the instructed position as directed by the technician.
  • After the Scan: Patients may resume normal activities. They should drink plenty of water to facilitate the excretion of radioactive substances via urine.

large_20200602_091841_875852_chup_pet_ct_co_an_t_max_1800x1800_jpg_cfbb5f8024

Guide to Scheduling PET/CT Imaging at Vinmec Times City

To arrange a suitable appointment and receive thorough medical preparation instructions from the physician (avoiding rescheduling due to errors in fasting or blood glucose testing), patients should proactively contact us to book in advance via:

  • Method 1: Call the hotline directly 0941.298.865 and provide booking information to the operator.
  • Method 2: Fill out all required information for the patient and the desired time slot on the Bcare appointment booking system. An operator will proactively contact you to confirm and advise.

Frequently Asked Questions About PET/CT Imaging at Vinmec

Is PET/CT imaging at Vinmec safe?

Yes. Many people worry about the radioactive substance injected into the body; however, the amount of 18F-FDG used falls within safe diagnostic limits, precisely calculated based on each individual's body weight.

Furthermore, this substance has a very short half-life (approximately 110 minutes). Six to eight hours after the scan, about 90% of the radioactivity has been naturally excreted from the body via urine. The modern equipment at Vinmec also significantly reduces the X-ray dose compared to conventional machines.

Is isolation required after PET/CT imaging?

No. Patients can eat, walk, and engage in normal activities immediately after the scan. However, to ensure absolute radiation safety for vulnerable groups such as pregnant women and young children, patients should drink plenty of water during the first 6–12 hours post-scan to accelerate drug excretion and avoid close contact.

What is the cost of PET/CT imaging at Vinmec Times City?

The cost of PET/CT imaging at Vinmec may vary depending on the time period. Please contact 0941.298.865 for consultation and updates on the specific price list at the time of the scan.

Does PET/CT imaging hurt?

No. Before the PET/CT scan, an intravenous line is established to inject the radiopharmaceutical; this process is similar to routine injections. Additionally, the scanning process itself is completely painless.

Can pregnant or breastfeeding women undergo the scan?

Pregnant women or those suspected of being pregnant have a relative contraindication due to the potential effects of X-rays and radioactive substances on the fetus.

For lactating women, the technique can still be performed if truly necessary, but the mother must stop direct breastfeeding and discard expressed breast milk for 24 hours after the scan.

Professional strengths

Vinmec Times City currently operates the GE Discovery MI DR PET/CT system with a 128-slice CT from the United States, one of the most modern PET/CT systems in the world, which helps patients achieve early cancer detection and effective treatment.

Workplace

  • •Vinmec Times City International Hospital

Location Bệnh viện Đa khoa Quốc tế Vinmec Times City